 {"id":5870,"date":"2026-05-06T15:46:34","date_gmt":"2026-05-06T07:46:34","guid":{"rendered":"https:\/\/oqitop.com\/?post_type=product&#038;p=5870"},"modified":"2026-05-06T15:46:34","modified_gmt":"2026-05-06T07:46:34","slug":"high-purity-platinum-mesh-electrode-for-electrochemical-laboratory-research","status":"publish","type":"product","link":"https:\/\/oqitop.com\/ar\/high-purity-platinum-mesh-electrode-for-electrochemical-laboratory-research\/","title":{"rendered":"High-Purity Platinum Mesh Electrode for Electrochemical Laboratory Research"},"content":{"rendered":"<h1 data-section-id=\"mzm7mz\" data-start=\"1101\" data-end=\"1122\">\u0648\u0635\u0641 \u0627\u0644\u0645\u0646\u062a\u062c<\/h1>\n<p data-start=\"1124\" data-end=\"1508\">Our <strong data-start=\"1128\" data-end=\"1167\">High-Purity Platinum Mesh Electrode<\/strong> is designed for electrochemical testing, conductivity analysis, corrosion research, catalyst evaluation, material testing, and laboratory R&amp;D applications. The electrode features a platinum mesh head with a straight metal rod connection, providing a large active surface area, excellent conductivity, and stable electrochemical performance.<\/p>\n<p data-start=\"1510\" data-end=\"1829\">The platinum mesh structure allows efficient contact with electrolyte solutions and supports stable current distribution during electrochemical experiments. It is suitable for beaker tests, electrochemical cells, three-electrode systems, corrosion studies, conductivity analysis, and research-level material evaluation.<\/p>\n<p data-start=\"1831\" data-end=\"2271\">We support <strong data-start=\"1842\" data-end=\"1964\">custom mesh size, mesh count, mesh shape, rod length, rod diameter, connection structure, and overall electrode design<\/strong> according to your experimental requirements. Whether you need a standard platinum mesh electrode, platinum mesh basket electrode, cylindrical mesh electrode, rectangular mesh electrode, or customized Pt electrode, we can provide flexible OEM \/ ODM solutions for laboratory and industrial research projects.<\/p>\n<hr data-start=\"2273\" data-end=\"2276\" \/>\n<h2 data-section-id=\"1ma7m6t\" data-start=\"2278\" data-end=\"2293\">Key Features<\/h2>\n<h3 data-section-id=\"30k3xn\" data-start=\"2295\" data-end=\"2328\">High-Purity Platinum Material<\/h3>\n<p data-start=\"2330\" data-end=\"2441\">Made with high-purity platinum material for reliable electrochemical performance and stable laboratory testing.<\/p>\n<h3 data-section-id=\"nfrjng\" data-start=\"2443\" data-end=\"2479\">Large Platinum Mesh Surface Area<\/h3>\n<p data-start=\"2481\" data-end=\"2622\">The mesh structure provides a larger effective reaction area than a solid sheet or wire electrode, supporting efficient current distribution.<\/p>\n<h3 data-section-id=\"1chze4d\" data-start=\"2624\" data-end=\"2650\">Excellent Conductivity<\/h3>\n<p data-start=\"2652\" data-end=\"2788\">Platinum offers excellent electrical conductivity, making it suitable for precision electrochemical testing and stable current transfer.<\/p>\n<h3 data-section-id=\"1xatq7z\" data-start=\"2790\" data-end=\"2825\">Corrosion &amp; Chemical Resistance<\/h3>\n<p data-start=\"2827\" data-end=\"2955\">Platinum has strong chemical stability and corrosion resistance, suitable for demanding laboratory electrochemical environments.<\/p>\n<h3 data-section-id=\"1qujkji\" data-start=\"2957\" data-end=\"2990\">Straight Metal Rod Connection<\/h3>\n<p data-start=\"2992\" data-end=\"3112\">The straight metal rod structure allows convenient installation, handling, and connection in laboratory testing systems.<\/p>\n<h3 data-section-id=\"igbgei\" data-start=\"3114\" data-end=\"3149\">Custom Mesh Structure Available<\/h3>\n<p data-start=\"3151\" data-end=\"3263\">Mesh size, mesh count, mesh shape, rod length, rod diameter, and overall structure can be customized on request.<\/p>\n<hr data-start=\"3265\" data-end=\"3268\" \/>\n<h2 data-section-id=\"1a3ueyz\" data-start=\"3270\" data-end=\"3287\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3289\" data-end=\"3949\">\n<thead data-start=\"3289\" data-end=\"3313\">\n<tr data-start=\"3289\" data-end=\"3313\">\n<th class=\"\" data-start=\"3289\" data-end=\"3296\" data-col-size=\"sm\">\u0627\u0644\u0628\u0646\u062f<\/th>\n<th class=\"\" data-start=\"3296\" data-end=\"3313\" data-col-size=\"md\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3324\" data-end=\"3949\">\n<tr data-start=\"3324\" data-end=\"3366\">\n<td data-start=\"3324\" data-end=\"3339\" data-col-size=\"sm\">Product Name<\/td>\n<td data-start=\"3339\" data-end=\"3366\" data-col-size=\"md\">Platinum Mesh Electrode<\/td>\n<\/tr>\n<tr data-start=\"3367\" data-end=\"3390\">\n<td data-start=\"3367\" data-end=\"3378\" data-col-size=\"sm\">\u0627\u0644\u0645\u0648\u0627\u062f<\/td>\n<td data-start=\"3378\" data-end=\"3390\" data-col-size=\"md\">Platinum<\/td>\n<\/tr>\n<tr data-start=\"3391\" data-end=\"3468\">\n<td data-start=\"3391\" data-end=\"3408\" data-col-size=\"sm\">Electrode Type<\/td>\n<td data-start=\"3408\" data-end=\"3468\" data-col-size=\"md\">Mesh Electrode \/ Counter Electrode \/ Auxiliary Electrode<\/td>\n<\/tr>\n<tr data-start=\"3469\" data-end=\"3538\">\n<td data-start=\"3469\" data-end=\"3482\" data-col-size=\"sm\">Mesh Shape<\/td>\n<td data-start=\"3482\" data-end=\"3538\" data-col-size=\"md\">Rectangular Cylindrical \/ Basket Type \/ Custom Shape<\/td>\n<\/tr>\n<tr data-start=\"3539\" data-end=\"3567\">\n<td data-start=\"3539\" data-end=\"3551\" data-col-size=\"sm\">Mesh Size<\/td>\n<td data-start=\"3551\" data-end=\"3567\" data-col-size=\"md\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3568\" data-end=\"3597\">\n<td data-start=\"3568\" data-end=\"3581\" data-col-size=\"sm\">Mesh Count<\/td>\n<td data-start=\"3581\" data-end=\"3597\" data-col-size=\"md\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3598\" data-end=\"3644\">\n<td data-start=\"3598\" data-end=\"3613\" data-col-size=\"sm\">Rod Material<\/td>\n<td data-start=\"3613\" data-end=\"3644\" data-col-size=\"md\">Platinum \/ Custom Metal Rod<\/td>\n<\/tr>\n<tr data-start=\"3645\" data-end=\"3674\">\n<td data-start=\"3645\" data-end=\"3658\" data-col-size=\"sm\">Rod Length<\/td>\n<td data-start=\"3658\" data-end=\"3674\" data-col-size=\"md\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3675\" data-end=\"3706\">\n<td data-start=\"3675\" data-end=\"3690\" data-col-size=\"sm\">Rod Diameter<\/td>\n<td data-start=\"3690\" data-end=\"3706\" data-col-size=\"md\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3707\" data-end=\"3747\">\n<td data-start=\"3707\" data-end=\"3717\" data-col-size=\"sm\">Surface<\/td>\n<td data-start=\"3717\" data-end=\"3747\" data-col-size=\"md\">Fine Platinum Mesh Surface<\/td>\n<\/tr>\n<tr data-start=\"3748\" data-end=\"3812\">\n<td data-start=\"3748\" data-end=\"3760\" data-col-size=\"sm\">Structure<\/td>\n<td data-start=\"3760\" data-end=\"3812\" data-col-size=\"md\">Mesh Basket with Straight Rod \/ Custom Structure<\/td>\n<\/tr>\n<tr data-start=\"3813\" data-end=\"3876\">\n<td data-start=\"3813\" data-end=\"3827\" data-col-size=\"sm\">\u0627\u0644\u062a\u0637\u0628\u064a\u0642<\/td>\n<td data-start=\"3827\" data-end=\"3876\" data-col-size=\"md\">Electrochemical Testing \/ Laboratory Research<\/td>\n<\/tr>\n<tr data-start=\"3877\" data-end=\"3949\">\n<td data-start=\"3877\" data-end=\"3894\" data-col-size=\"sm\">Custom Service<\/td>\n<td data-start=\"3894\" data-end=\"3949\" data-col-size=\"md\">Mesh Size, Mesh Count, Shape, Rod Length, Structure<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"3951\" data-end=\"3954\" \/>\n<h2 data-section-id=\"mu966k\" data-start=\"3956\" data-end=\"3971\">Applications<\/h2>\n<ul data-start=\"3973\" data-end=\"4415\">\n<li data-section-id=\"efj2kc\" data-start=\"3973\" data-end=\"3998\">Electrochemical testing<\/li>\n<li data-section-id=\"1svj8jf\" data-start=\"3999\" data-end=\"4035\">Three-electrode system experiments<\/li>\n<li data-section-id=\"il0q84\" data-start=\"4036\" data-end=\"4077\">Platinum counter electrode applications<\/li>\n<li data-section-id=\"j95bay\" data-start=\"4078\" data-end=\"4121\">Platinum auxiliary electrode applications<\/li>\n<li data-section-id=\"3pmmmd\" data-start=\"4122\" data-end=\"4145\">Conductivity analysis<\/li>\n<li data-section-id=\"ohwo5l\" data-start=\"4146\" data-end=\"4166\">Corrosion research<\/li>\n<li data-section-id=\"8vdj4r\" data-start=\"4167\" data-end=\"4188\">Catalyst evaluation<\/li>\n<li data-section-id=\"1m9nk5p\" data-start=\"4189\" data-end=\"4219\">Material performance testing<\/li>\n<li data-section-id=\"vg6tcr\" data-start=\"4220\" data-end=\"4236\">Laboratory R&amp;D<\/li>\n<li data-section-id=\"9ucn4w\" data-start=\"4237\" data-end=\"4257\">Beaker experiments<\/li>\n<li data-section-id=\"1g0hygq\" data-start=\"4258\" data-end=\"4288\">Electrochemical cell testing<\/li>\n<li data-section-id=\"vubkk7\" data-start=\"4289\" data-end=\"4316\">Battery material research<\/li>\n<li data-section-id=\"10fivlz\" data-start=\"4317\" data-end=\"4334\">Sensor research<\/li>\n<li data-section-id=\"1xf2m4j\" data-start=\"4335\" data-end=\"4362\">Chemical solution testing<\/li>\n<li data-section-id=\"3bq1of\" data-start=\"4363\" data-end=\"4385\">Academic experiments<\/li>\n<li data-section-id=\"9er28i\" data-start=\"4386\" data-end=\"4415\">Industrial material testing<\/li>\n<\/ul>\n<hr data-start=\"4417\" data-end=\"4420\" \/>\n<h2 data-section-id=\"dysc5y\" data-start=\"4422\" data-end=\"4443\">\u0645\u0632\u0627\u064a\u0627 \u0627\u0644\u0645\u0646\u062a\u062c<\/h2>\n<h3 data-section-id=\"c0ieom\" data-start=\"4445\" data-end=\"4478\">Suitable as Counter Electrode<\/h3>\n<p data-start=\"4480\" data-end=\"4604\">Platinum mesh electrodes are commonly used as counter electrodes or auxiliary electrodes in electrochemical testing systems.<\/p>\n<h3 data-section-id=\"bf05h4\" data-start=\"4606\" data-end=\"4637\">Stable Current Distribution<\/h3>\n<p data-start=\"4639\" data-end=\"4758\">The mesh structure provides a large effective contact area, helping improve current distribution and testing stability.<\/p>\n<h3 data-section-id=\"iau4n2\" data-start=\"4760\" data-end=\"4789\">Easy Laboratory Operation<\/h3>\n<p data-start=\"4791\" data-end=\"4924\">The straight rod and mesh basket structure are convenient for use in beakers, electrochemical cells, clamps, and laboratory fixtures.<\/p>\n<h3 data-section-id=\"1wezeyn\" data-start=\"4926\" data-end=\"4957\">Reliable Chemical Stability<\/h3>\n<p data-start=\"4959\" data-end=\"5060\">Platinum provides excellent corrosion resistance and chemical stability for long-term laboratory use.<\/p>\n<h3 data-section-id=\"7buu87\" data-start=\"5062\" data-end=\"5083\">OEM \/ ODM Support<\/h3>\n<p data-start=\"5085\" data-end=\"5220\">Custom mesh size, mesh count, rod length, rod diameter, mesh shape, and packaging are available according to your project requirements.<\/p>\n<hr data-start=\"5222\" data-end=\"5225\" \/>\n<h2 data-section-id=\"1hryhf7\" data-start=\"5227\" data-end=\"5233\">FAQ<\/h2>\n<h3 data-section-id=\"1ncabt6\" data-start=\"5235\" data-end=\"5280\">Can the platinum mesh size be customized?<\/h3>\n<p data-start=\"5282\" data-end=\"5442\">Yes. Mesh size, mesh count, mesh shape, rod length, rod diameter, and overall electrode structure can be customized according to your experimental requirements.<\/p>\n<h3 data-section-id=\"16mt1ou\" data-start=\"5444\" data-end=\"5493\">What is the platinum mesh electrode used for?<\/h3>\n<p data-start=\"5495\" data-end=\"5645\">It is commonly used for electrochemical testing, conductivity analysis, corrosion research, catalyst evaluation, material testing, and laboratory R&amp;D.<\/p>\n<h3 data-section-id=\"z546lw\" data-start=\"5647\" data-end=\"5701\">Can this electrode be used as a counter electrode?<\/h3>\n<p data-start=\"5703\" data-end=\"5838\">Yes. Platinum mesh electrodes are widely used as counter electrodes or auxiliary electrodes in three-electrode electrochemical systems.<\/p>\n<h3 data-section-id=\"1slo6pq\" data-start=\"5840\" data-end=\"5882\">Can the mesh head shape be customized?<\/h3>\n<p data-start=\"5884\" data-end=\"6040\">Yes. Rectangular cylindrical, basket type, flat mesh, cylindrical mesh, and special custom structures can be produced according to your drawings or samples.<\/p>\n<h3 data-section-id=\"9ailx1\" data-start=\"6042\" data-end=\"6077\">Is the rod length customizable?<\/h3>\n<p data-start=\"6079\" data-end=\"6206\">Yes. Rod length, rod diameter, and connection structure can be customized according to your testing cell or experimental setup.<\/p>\n<h3 data-section-id=\"16i3rrh\" data-start=\"6208\" data-end=\"6251\">Do you support OEM \/ ODM customization?<\/h3>\n<p data-start=\"6253\" data-end=\"6399\">Yes. We support custom size, custom structure, custom mesh count, custom rod length, custom material selection, and OEM \/ ODM processing services.<\/p>","protected":false},"featured_media":5874,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"tags":[],"products":[268,279],"class_list":["post-5870","product","type-product","status-publish","has-post-thumbnail","hentry","products-metal-electrode","products-platinum-electrode"],"acf":[],"_links":{"self":[{"href":"https:\/\/oqitop.com\/ar\/wp-json\/wp\/v2\/product\/5870","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oqitop.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/oqitop.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oqitop.com\/ar\/wp-json\/wp\/v2\/media\/5874"}],"wp:attachment":[{"href":"https:\/\/oqitop.com\/ar\/wp-json\/wp\/v2\/media?parent=5870"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oqitop.com\/ar\/wp-json\/wp\/v2\/tags?post=5870"},{"taxonomy":"products","embeddable":true,"href":"https:\/\/oqitop.com\/ar\/wp-json\/wp\/v2\/products?post=5870"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}