 {"id":5805,"date":"2026-05-06T10:39:09","date_gmt":"2026-05-06T02:39:09","guid":{"rendered":"https:\/\/oqitop.com\/?post_type=product&#038;p=5805"},"modified":"2026-05-06T10:39:09","modified_gmt":"2026-05-06T02:39:09","slug":"high-purity-platinum-mesh-electrode-for-electrochemical-research","status":"publish","type":"product","link":"https:\/\/oqitop.com\/de\/high-purity-platinum-mesh-electrode-for-electrochemical-research\/","title":{"rendered":"High-Purity Platinum Mesh Electrode for Electrochemical Research"},"content":{"rendered":"<h1 data-section-id=\"mzm7mz\" data-start=\"1140\" data-end=\"1161\">Produktbeschreibung<\/h1>\n<p data-start=\"1163\" data-end=\"1531\">Our <strong data-start=\"1167\" data-end=\"1206\">High-Purity Platinum Mesh Electrode<\/strong> is designed for laboratory electrochemical testing, conductivity analysis, corrosion research, and material development applications. Made with <strong data-start=\"1351\" data-end=\"1376\">\u226599.99% platinum mesh<\/strong>, this electrode provides excellent conductivity, strong corrosion resistance, and stable electrochemical performance for precision laboratory experiments.<\/p>\n<p data-start=\"1533\" data-end=\"2010\">The electrode features a platinum mesh tip, an insulating rod body, a sealing O-ring, and a metal connector pin for convenient connection with electrochemical workstations, potentiostats, electrode holders, and laboratory testing systems. The platinum mesh structure provides a larger effective surface area than solid platinum wire or sheet electrodes, making it suitable for use as a <strong data-start=\"1919\" data-end=\"1962\">counter electrode \/ auxiliary electrode<\/strong> in a wide range of electrochemical experiments.<\/p>\n<p data-start=\"2012\" data-end=\"2286\">We support <strong data-start=\"2023\" data-end=\"2132\">custom rod length, rod diameter, mesh size, connector pin, insulating rod material, and overall structure<\/strong> according to your testing requirements. PTFE and PEEK insulating rod options are available for different chemical environments and research applications.<\/p>\n<hr data-start=\"2288\" data-end=\"2291\" \/>\n<h2 data-section-id=\"1ma7m6t\" data-start=\"2293\" data-end=\"2308\">Key Features<\/h2>\n<h3 data-section-id=\"1vt5w1f\" data-start=\"2310\" data-end=\"2339\">High-Purity Platinum Mesh<\/h3>\n<p data-start=\"2341\" data-end=\"2447\">Made with \u226599.99% platinum mesh for reliable electrochemical performance and precision laboratory testing.<\/p>\n<h3 data-section-id=\"1chze4d\" data-start=\"2449\" data-end=\"2475\">Excellent Conductivity<\/h3>\n<p data-start=\"2477\" data-end=\"2592\">Platinum provides stable current transfer and excellent electrical conductivity during electrochemical experiments.<\/p>\n<h3 data-section-id=\"it9rpw\" data-start=\"2594\" data-end=\"2626\">Large Effective Surface Area<\/h3>\n<p data-start=\"2628\" data-end=\"2737\">The mesh structure offers a larger reaction area, helping improve current distribution and testing stability.<\/p>\n<h3 data-section-id=\"17g2ogf\" data-start=\"2739\" data-end=\"2762\">Corrosion Resistant<\/h3>\n<p data-start=\"2764\" data-end=\"2858\">Suitable for demanding chemical environments, corrosion studies, and long-term laboratory use.<\/p>\n<h3 data-section-id=\"1ey1rq4\" data-start=\"2860\" data-end=\"2887\">PTFE \/ PEEK Rod Options<\/h3>\n<p data-start=\"2889\" data-end=\"3013\">Insulating rod material can be customized with PTFE, PEEK, or other suitable materials according to experimental conditions.<\/p>\n<h3 data-section-id=\"kuceah\" data-start=\"3015\" data-end=\"3041\">Customizable Structure<\/h3>\n<p data-start=\"3043\" data-end=\"3160\">Rod length, rod diameter, connector pin, mesh size, mesh shape, and electrode structure can be customized on request.<\/p>\n<hr data-start=\"3162\" data-end=\"3165\" \/>\n<h2 data-section-id=\"1a3ueyz\" data-start=\"3167\" data-end=\"3184\">Spezifikationen<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3186\" data-end=\"3851\">\n<thead data-start=\"3186\" data-end=\"3210\">\n<tr data-start=\"3186\" data-end=\"3210\">\n<th class=\"\" data-start=\"3186\" data-end=\"3193\" data-col-size=\"sm\">Artikel<\/th>\n<th class=\"\" data-start=\"3193\" data-end=\"3210\" data-col-size=\"md\">Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3221\" data-end=\"3851\">\n<tr data-start=\"3221\" data-end=\"3263\">\n<td data-start=\"3221\" data-end=\"3236\" data-col-size=\"sm\">Produktname<\/td>\n<td data-start=\"3236\" data-end=\"3263\" data-col-size=\"md\">Platinum Mesh Electrode<\/td>\n<\/tr>\n<tr data-start=\"3264\" data-end=\"3304\">\n<td data-start=\"3264\" data-end=\"3275\" data-col-size=\"sm\">Material<\/td>\n<td data-start=\"3275\" data-end=\"3304\" data-col-size=\"md\">High-Purity Platinum Mesh<\/td>\n<\/tr>\n<tr data-start=\"3305\" data-end=\"3328\">\n<td data-start=\"3305\" data-end=\"3314\" data-col-size=\"sm\">Reinheit<\/td>\n<td data-start=\"3314\" data-end=\"3328\" data-col-size=\"md\">\u226599.99% Pt<\/td>\n<\/tr>\n<tr data-start=\"3329\" data-end=\"3389\">\n<td data-start=\"3329\" data-end=\"3346\" data-col-size=\"sm\">Electrode Type<\/td>\n<td data-start=\"3346\" data-end=\"3389\" data-col-size=\"md\">Counter Electrode \/ Auxiliary Electrode<\/td>\n<\/tr>\n<tr data-start=\"3390\" data-end=\"3441\">\n<td data-start=\"3390\" data-end=\"3407\" data-col-size=\"sm\">Insulating Rod<\/td>\n<td data-start=\"3407\" data-end=\"3441\" data-col-size=\"md\">PTFE \/ PEEK \/ Custom Available<\/td>\n<\/tr>\n<tr data-start=\"3442\" data-end=\"3490\">\n<td data-start=\"3442\" data-end=\"3458\" data-col-size=\"sm\">Connector Pin<\/td>\n<td data-start=\"3458\" data-end=\"3490\" data-col-size=\"md\">Metal Pin \/ Custom Connector<\/td>\n<\/tr>\n<tr data-start=\"3491\" data-end=\"3516\">\n<td data-start=\"3491\" data-end=\"3506\" data-col-size=\"sm\">Sealing Part<\/td>\n<td data-start=\"3506\" data-end=\"3516\" data-col-size=\"md\">O-Ring<\/td>\n<\/tr>\n<tr data-start=\"3517\" data-end=\"3546\">\n<td data-start=\"3517\" data-end=\"3530\" data-col-size=\"sm\">Rod Length<\/td>\n<td data-start=\"3530\" data-end=\"3546\" data-col-size=\"md\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3547\" data-end=\"3578\">\n<td data-start=\"3547\" data-end=\"3562\" data-col-size=\"sm\">Rod Diameter<\/td>\n<td data-start=\"3562\" data-end=\"3578\" data-col-size=\"md\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3579\" data-end=\"3607\">\n<td data-start=\"3579\" data-end=\"3591\" data-col-size=\"sm\">Mesh Size<\/td>\n<td data-start=\"3591\" data-end=\"3607\" data-col-size=\"md\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3608\" data-end=\"3660\">\n<td data-start=\"3608\" data-end=\"3621\" data-col-size=\"sm\">Mesh Shape<\/td>\n<td data-start=\"3621\" data-end=\"3660\" data-col-size=\"md\">Rectangular \/ Square \/ Custom Shape<\/td>\n<\/tr>\n<tr data-start=\"3661\" data-end=\"3708\">\n<td data-start=\"3661\" data-end=\"3673\" data-col-size=\"sm\">Structure<\/td>\n<td data-start=\"3673\" data-end=\"3708\" data-col-size=\"md\">Straight Rod \/ Custom Structure<\/td>\n<\/tr>\n<tr data-start=\"3709\" data-end=\"3772\">\n<td data-start=\"3709\" data-end=\"3723\" data-col-size=\"sm\">Anwendung<\/td>\n<td data-start=\"3723\" data-end=\"3772\" data-col-size=\"md\">Electrochemical Testing \/ Laboratory Research<\/td>\n<\/tr>\n<tr data-start=\"3773\" data-end=\"3851\">\n<td data-start=\"3773\" data-end=\"3790\" data-col-size=\"sm\">Custom Service<\/td>\n<td data-start=\"3790\" data-end=\"3851\" data-col-size=\"md\">Rod Length, Rod Diameter, Mesh Size, Connector, Structure<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"3853\" data-end=\"3856\" \/>\n<h2 data-section-id=\"mu966k\" data-start=\"3858\" data-end=\"3873\">Applications<\/h2>\n<ul data-start=\"3875\" data-end=\"4261\">\n<li data-section-id=\"efj2kc\" data-start=\"3875\" data-end=\"3900\">Electrochemical testing<\/li>\n<li data-section-id=\"yn19zm\" data-start=\"3901\" data-end=\"3933\">Counter electrode applications<\/li>\n<li data-section-id=\"1gbulws\" data-start=\"3934\" data-end=\"3968\">Auxiliary electrode applications<\/li>\n<li data-section-id=\"3pmmmd\" data-start=\"3969\" data-end=\"3992\">Conductivity analysis<\/li>\n<li data-section-id=\"ohwo5l\" data-start=\"3993\" data-end=\"4013\">Corrosion research<\/li>\n<li data-section-id=\"148qsfh\" data-start=\"4014\" data-end=\"4047\">Material performance evaluation<\/li>\n<li data-section-id=\"vg6tcr\" data-start=\"4048\" data-end=\"4064\">Laboratory R&amp;D<\/li>\n<li data-section-id=\"1v5ogms\" data-start=\"4065\" data-end=\"4089\">Potentiostatic testing<\/li>\n<li data-section-id=\"1ihx9ju\" data-start=\"4090\" data-end=\"4113\">Galvanostatic testing<\/li>\n<li data-section-id=\"9ucn4w\" data-start=\"4114\" data-end=\"4134\">Beaker experiments<\/li>\n<li data-section-id=\"1g0hygq\" data-start=\"4135\" data-end=\"4165\">Electrochemical cell testing<\/li>\n<li data-section-id=\"vubkk7\" data-start=\"4166\" data-end=\"4193\">Battery material research<\/li>\n<li data-section-id=\"6mclbo\" data-start=\"4194\" data-end=\"4213\">Catalyst research<\/li>\n<li data-section-id=\"1xf2m4j\" data-start=\"4214\" data-end=\"4241\">Chemical solution testing<\/li>\n<li data-section-id=\"izno38\" data-start=\"4242\" data-end=\"4261\">Academic research<\/li>\n<\/ul>\n<hr data-start=\"4263\" data-end=\"4266\" \/>\n<h2 data-section-id=\"dysc5y\" data-start=\"4268\" data-end=\"4289\">Product Advantages<\/h2>\n<h3 data-section-id=\"1x1nbzl\" data-start=\"4291\" data-end=\"4329\">Stable Electrochemical Performance<\/h3>\n<p data-start=\"4331\" data-end=\"4454\">The high-purity platinum mesh provides stable conductivity and reliable electrochemical response for precision experiments.<\/p>\n<h3 data-section-id=\"1b6e10y\" data-start=\"4456\" data-end=\"4492\">Suitable as Pt Counter Electrode<\/h3>\n<p data-start=\"4494\" data-end=\"4615\">The electrode can be used as a platinum counter electrode or auxiliary electrode in many electrochemical testing systems.<\/p>\n<h3 data-section-id=\"iau4n2\" data-start=\"4617\" data-end=\"4646\">Easy Laboratory Operation<\/h3>\n<p data-start=\"4648\" data-end=\"4783\">The rod-type structure is convenient for use in beakers, electrochemical cells, three-electrode systems, and research testing fixtures.<\/p>\n<h3 data-section-id=\"mn51rb\" data-start=\"4785\" data-end=\"4816\">Custom Processing Available<\/h3>\n<p data-start=\"4818\" data-end=\"4951\">We can customize the platinum mesh size, rod length, rod diameter, connector style, insulating rod material, and electrode structure.<\/p>\n<h3 data-section-id=\"7gj8p6\" data-start=\"4953\" data-end=\"4990\">Designed for Research and Testing<\/h3>\n<p data-start=\"4992\" data-end=\"5156\">Suitable for universities, laboratories, research institutes, electrochemical workstations, corrosion studies, catalyst research, and material development projects.<\/p>\n<hr data-start=\"5158\" data-end=\"5161\" \/>\n<h2 data-section-id=\"1hryhf7\" data-start=\"5163\" data-end=\"5169\">FAQ<\/h2>\n<h3 data-section-id=\"1ncabt6\" data-start=\"5171\" data-end=\"5216\">Can the platinum mesh size be customized?<\/h3>\n<p data-start=\"5218\" data-end=\"5381\">Yes. Platinum mesh size, mesh shape, rod length, rod diameter, connector type, and overall structure can be customized according to your experimental requirements.<\/p>\n<h3 data-section-id=\"1ql3eo3\" data-start=\"5383\" data-end=\"5412\">What purity is available?<\/h3>\n<p data-start=\"5414\" data-end=\"5526\">Standard purity can be <strong data-start=\"5437\" data-end=\"5451\">\u226599.99% Pt<\/strong>. Other purity requirements can be discussed according to your application.<\/p>\n<h3 data-section-id=\"z546lw\" data-start=\"5528\" data-end=\"5582\">Can this electrode be used as a counter electrode?<\/h3>\n<p data-start=\"5584\" data-end=\"5707\">Yes. Platinum mesh electrodes are widely used as counter electrodes or auxiliary electrodes in electrochemical experiments.<\/p>\n<h3 data-section-id=\"1l2bh41\" data-start=\"5709\" data-end=\"5770\">Can I choose PTFE or PEEK as the insulating rod material?<\/h3>\n<p data-start=\"5772\" data-end=\"5923\">Yes. PTFE and PEEK insulating rod options are available. The rod material can be selected according to the chemical environment and testing conditions.<\/p>\n<h3 data-section-id=\"ysnik8\" data-start=\"5925\" data-end=\"5966\">What instruments can it connect with?<\/h3>\n<p data-start=\"5968\" data-end=\"6112\">It can be used with electrochemical workstations, potentiostats, electrode holders, three-electrode cells, and other laboratory testing systems.<\/p>\n<h3 data-section-id=\"16i3rrh\" data-start=\"6114\" data-end=\"6157\">Do you support OEM \/ ODM customization?<\/h3>\n<p data-start=\"6159\" data-end=\"6285\">Yes. We support custom size, custom structure, custom material selection, custom connector, and OEM \/ ODM processing services.<\/p>","protected":false},"featured_media":5806,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"tags":[],"products":[268,279],"class_list":["post-5805","product","type-product","status-publish","has-post-thumbnail","hentry","products-metal-electrode","products-platinum-electrode"],"acf":[],"_links":{"self":[{"href":"https:\/\/oqitop.com\/de\/wp-json\/wp\/v2\/product\/5805","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oqitop.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/oqitop.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oqitop.com\/de\/wp-json\/wp\/v2\/media\/5806"}],"wp:attachment":[{"href":"https:\/\/oqitop.com\/de\/wp-json\/wp\/v2\/media?parent=5805"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oqitop.com\/de\/wp-json\/wp\/v2\/tags?post=5805"},{"taxonomy":"products","embeddable":true,"href":"https:\/\/oqitop.com\/de\/wp-json\/wp\/v2\/products?post=5805"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}