 {"id":5647,"date":"2026-05-05T11:04:57","date_gmt":"2026-05-05T03:04:57","guid":{"rendered":"https:\/\/oqitop.com\/?post_type=product&#038;p=5647"},"modified":"2026-05-05T11:04:57","modified_gmt":"2026-05-05T03:04:57","slug":"100-%ce%bcm-pet-flexible-interdigitated-gold-electrode-for-electrochemical-sensors","status":"publish","type":"product","link":"https:\/\/oqitop.com\/fr\/100-%CE%BCm-pet-flexible-interdigitated-gold-electrode-for-electrochemical-sensors\/","title":{"rendered":"100 \u03bcm PET Flexible Interdigitated Gold Electrode for Electrochemical Sensors"},"content":{"rendered":"<h2 data-section-id=\"1bw7wp4\" data-start=\"262\" data-end=\"284\">Description du produit<\/h2>\n<p data-start=\"286\" data-end=\"702\"><strong data-start=\"286\" data-end=\"345\">100 \u03bcm Polyester Flexible Interdigitated Gold Electrode<\/strong> is a flexible electrochemical electrode designed for biosensors, electrochemical sensors, impedance testing, microfluidic devices, wearable electronics, and laboratory electrochemical research. The electrode is fabricated on a thin polyester \/ PET flexible substrate with patterned gold conductive fingers, providing a stable and well-defined sensing area.<\/p>\n<p data-start=\"704\" data-end=\"982\">The interdigitated finger structure increases the effective electrode interface and shortens the diffusion distance between electrodes, making it suitable for high-sensitivity electrochemical detection, impedance analysis, conductivity testing, and surface modification studies.<\/p>\n<p data-start=\"984\" data-end=\"1137\">This flexible gold electrode can be used in liquid samples, biological testing, chemical detection, material research, and customized sensor development.<\/p>\n<p data-start=\"1266\" data-end=\"1341\">\n<hr data-start=\"1343\" data-end=\"1346\" \/>\n<h2 data-section-id=\"1ma7m6t\" data-start=\"1348\" data-end=\"1363\">Key Features<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1365\" data-end=\"1925\">\n<thead data-start=\"1365\" data-end=\"1387\">\n<tr data-start=\"1365\" data-end=\"1387\">\n<th class=\"\" data-start=\"1365\" data-end=\"1372\" data-col-size=\"sm\">Objet<\/th>\n<th class=\"\" data-start=\"1372\" data-end=\"1387\" data-col-size=\"md\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1398\" data-end=\"1925\">\n<tr data-start=\"1398\" data-end=\"1455\">\n<td data-start=\"1398\" data-end=\"1413\" data-col-size=\"sm\">Product Name<\/td>\n<td data-col-size=\"md\" data-start=\"1413\" data-end=\"1455\">Flexible Interdigitated Gold Electrode<\/td>\n<\/tr>\n<tr data-start=\"1456\" data-end=\"1496\">\n<td data-start=\"1456\" data-end=\"1477\" data-col-size=\"sm\">Substrate Material<\/td>\n<td data-col-size=\"md\" data-start=\"1477\" data-end=\"1496\">Polyester \/ PET<\/td>\n<\/tr>\n<tr data-start=\"1497\" data-end=\"1529\">\n<td data-start=\"1497\" data-end=\"1519\" data-col-size=\"sm\">Substrate Thickness<\/td>\n<td data-col-size=\"md\" data-start=\"1519\" data-end=\"1529\">100 \u03bcm<\/td>\n<\/tr>\n<tr data-start=\"1530\" data-end=\"1564\">\n<td data-start=\"1530\" data-end=\"1551\" data-col-size=\"sm\">Electrode Material<\/td>\n<td data-col-size=\"md\" data-start=\"1551\" data-end=\"1564\">Gold \/ Au<\/td>\n<\/tr>\n<tr data-start=\"1565\" data-end=\"1629\">\n<td data-start=\"1565\" data-end=\"1582\" data-col-size=\"sm\">Electrode Type<\/td>\n<td data-col-size=\"md\" data-start=\"1582\" data-end=\"1629\">Interdigitated electrode \/ finger electrode<\/td>\n<\/tr>\n<tr data-start=\"1630\" data-end=\"1691\">\n<td data-start=\"1630\" data-end=\"1642\" data-col-size=\"sm\">Structure<\/td>\n<td data-col-size=\"md\" data-start=\"1642\" data-end=\"1691\">Two-electrode \/ bipolar interdigitated design<\/td>\n<\/tr>\n<tr data-start=\"1692\" data-end=\"1734\">\n<td data-start=\"1692\" data-end=\"1706\" data-col-size=\"sm\">Flexibilit\u00e9<\/td>\n<td data-start=\"1706\" data-end=\"1734\" data-col-size=\"md\">Flexible and lightweight<\/td>\n<\/tr>\n<tr data-start=\"1735\" data-end=\"1772\">\n<td data-start=\"1735\" data-end=\"1745\" data-col-size=\"sm\">Surface<\/td>\n<td data-col-size=\"md\" data-start=\"1745\" data-end=\"1772\">Gold conductive pattern<\/td>\n<\/tr>\n<tr data-start=\"1773\" data-end=\"1846\">\n<td data-start=\"1773\" data-end=\"1787\" data-col-size=\"sm\">Application<\/td>\n<td data-col-size=\"md\" data-start=\"1787\" data-end=\"1846\">Electrochemical sensing, biosensors, impedance analysis<\/td>\n<\/tr>\n<tr data-start=\"1847\" data-end=\"1925\">\n<td data-start=\"1847\" data-end=\"1863\" data-col-size=\"sm\">Customization<\/td>\n<td data-col-size=\"md\" data-start=\"1863\" data-end=\"1925\">Electrode size, finger width, gap, pattern, connector area<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"1927\" data-end=\"1930\" \/>\n<h2 data-section-id=\"1klznxy\" data-start=\"1932\" data-end=\"1950\">Main Advantages<\/h2>\n<ul data-start=\"1952\" data-end=\"2426\">\n<li data-section-id=\"1g4tnlk\" data-start=\"1952\" data-end=\"1996\">100 \u03bcm thin polyester flexible substrate<\/li>\n<li data-section-id=\"1pvup7f\" data-start=\"1997\" data-end=\"2041\">High-conductivity gold electrode pattern<\/li>\n<li data-section-id=\"1gyyhwr\" data-start=\"2042\" data-end=\"2077\">Interdigitated finger structure<\/li>\n<li data-section-id=\"h1sa11\" data-start=\"2078\" data-end=\"2129\">Suitable for electrochemical sensor development<\/li>\n<li data-section-id=\"5y4u\" data-start=\"2130\" data-end=\"2178\">Flexible, lightweight, and easy to integrate<\/li>\n<li data-section-id=\"18tqbzi\" data-start=\"2179\" data-end=\"2222\">Good surface modification compatibility<\/li>\n<li data-section-id=\"g87dgb\" data-start=\"2223\" data-end=\"2269\">Suitable for small-volume liquid detection<\/li>\n<li data-section-id=\"1qvy0ch\" data-start=\"2270\" data-end=\"2324\">Can be used for impedance and conductivity testing<\/li>\n<li data-section-id=\"1jacfhp\" data-start=\"2325\" data-end=\"2363\">Custom electrode pattern available<\/li>\n<li data-section-id=\"1x8po8s\" data-start=\"2364\" data-end=\"2426\">Suitable for disposable or research-grade sensor platforms<\/li>\n<\/ul>\n<hr data-start=\"2428\" data-end=\"2431\" \/>\n<h2 data-section-id=\"164os46\" data-start=\"2433\" data-end=\"2456\">Typical Applications<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2458\" data-end=\"3270\">\n<thead data-start=\"2458\" data-end=\"2487\">\n<tr data-start=\"2458\" data-end=\"2487\">\n<th class=\"\" data-start=\"2458\" data-end=\"2472\" data-col-size=\"sm\">Application<\/th>\n<th class=\"\" data-start=\"2472\" data-end=\"2487\" data-col-size=\"md\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2498\" data-end=\"3270\">\n<tr data-start=\"2498\" data-end=\"2570\">\n<td data-start=\"2498\" data-end=\"2524\" data-col-size=\"sm\">Electrochemical Sensors<\/td>\n<td data-col-size=\"md\" data-start=\"2524\" data-end=\"2570\">Used for chemical and biological detection<\/td>\n<\/tr>\n<tr data-start=\"2571\" data-end=\"2645\">\n<td data-start=\"2571\" data-end=\"2584\" data-col-size=\"sm\">Biosensors<\/td>\n<td data-col-size=\"md\" data-start=\"2584\" data-end=\"2645\">Suitable for enzyme, DNA, protein, and cell-based sensors<\/td>\n<\/tr>\n<tr data-start=\"2646\" data-end=\"2712\">\n<td data-start=\"2646\" data-end=\"2666\" data-col-size=\"sm\">Impedance Testing<\/td>\n<td data-col-size=\"md\" data-start=\"2666\" data-end=\"2712\">Used for EIS and impedance-based detection<\/td>\n<\/tr>\n<tr data-start=\"2713\" data-end=\"2797\">\n<td data-start=\"2713\" data-end=\"2740\" data-col-size=\"sm\">Conductivity Measurement<\/td>\n<td data-col-size=\"md\" data-start=\"2740\" data-end=\"2797\">Suitable for liquid conductivity and material testing<\/td>\n<\/tr>\n<tr data-start=\"2798\" data-end=\"2867\">\n<td data-start=\"2798\" data-end=\"2821\" data-col-size=\"sm\">Microfluidic Devices<\/td>\n<td data-col-size=\"md\" data-start=\"2821\" data-end=\"2867\">Can be integrated into lab-on-chip systems<\/td>\n<\/tr>\n<tr data-start=\"2868\" data-end=\"2945\">\n<td data-start=\"2868\" data-end=\"2891\" data-col-size=\"sm\">Wearable Electronics<\/td>\n<td data-col-size=\"md\" data-start=\"2891\" data-end=\"2945\">Flexible substrate supports wearable sensor design<\/td>\n<\/tr>\n<tr data-start=\"2946\" data-end=\"3044\">\n<td data-start=\"2946\" data-end=\"2969\" data-col-size=\"sm\">Surface Modification<\/td>\n<td data-col-size=\"md\" data-start=\"2969\" data-end=\"3044\">Gold surface supports functional coating and biomolecule immobilization<\/td>\n<\/tr>\n<tr data-start=\"3045\" data-end=\"3120\">\n<td data-start=\"3045\" data-end=\"3069\" data-col-size=\"sm\">Environmental Testing<\/td>\n<td data-col-size=\"md\" data-start=\"3069\" data-end=\"3120\">Used for ion, pollutant, and chemical detection<\/td>\n<\/tr>\n<tr data-start=\"3121\" data-end=\"3195\">\n<td data-start=\"3121\" data-end=\"3140\" data-col-size=\"sm\">Medical Research<\/td>\n<td data-col-size=\"md\" data-start=\"3140\" data-end=\"3195\">Suitable for flexible diagnostic sensor development<\/td>\n<\/tr>\n<tr data-start=\"3196\" data-end=\"3270\">\n<td data-start=\"3196\" data-end=\"3216\" data-col-size=\"sm\">Material Research<\/td>\n<td data-col-size=\"md\" data-start=\"3216\" data-end=\"3270\">Used for thin film, coating, and interface studies<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"3272\" data-end=\"3275\" \/>\n<h2 data-section-id=\"3aj7dy\" data-start=\"3277\" data-end=\"3301\">Common Specifications<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3303\" data-end=\"3775\">\n<thead data-start=\"3303\" data-end=\"3333\">\n<tr data-start=\"3303\" data-end=\"3333\">\n<th class=\"\" data-start=\"3303\" data-end=\"3315\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"\" data-start=\"3315\" data-end=\"3333\" data-col-size=\"sm\">Common Options<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3344\" data-end=\"3775\">\n<tr data-start=\"3344\" data-end=\"3375\">\n<td data-start=\"3344\" data-end=\"3356\" data-col-size=\"sm\">Substrate<\/td>\n<td data-col-size=\"sm\" data-start=\"3356\" data-end=\"3375\">PET \/ Polyester<\/td>\n<\/tr>\n<tr data-start=\"3376\" data-end=\"3408\">\n<td data-start=\"3376\" data-end=\"3398\" data-col-size=\"sm\">Substrate Thickness<\/td>\n<td data-col-size=\"sm\" data-start=\"3398\" data-end=\"3408\">100 \u03bcm<\/td>\n<\/tr>\n<tr data-start=\"3409\" data-end=\"3438\">\n<td data-start=\"3409\" data-end=\"3430\" data-col-size=\"sm\">Electrode Material<\/td>\n<td data-col-size=\"sm\" data-start=\"3430\" data-end=\"3438\">Gold<\/td>\n<\/tr>\n<tr data-start=\"3439\" data-end=\"3493\">\n<td data-start=\"3439\" data-end=\"3461\" data-col-size=\"sm\">Electrode Structure<\/td>\n<td data-start=\"3461\" data-end=\"3493\" data-col-size=\"sm\">Interdigitated \/ finger type<\/td>\n<\/tr>\n<tr data-start=\"3494\" data-end=\"3542\">\n<td data-start=\"3494\" data-end=\"3517\" data-col-size=\"sm\">Number of Electrodes<\/td>\n<td data-col-size=\"sm\" data-start=\"3517\" data-end=\"3542\">2-electrode \/ bipolar<\/td>\n<\/tr>\n<tr data-start=\"3543\" data-end=\"3577\">\n<td data-start=\"3543\" data-end=\"3561\" data-col-size=\"sm\">Electrode Width<\/td>\n<td data-col-size=\"sm\" data-start=\"3561\" data-end=\"3577\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3578\" data-end=\"3610\">\n<td data-start=\"3578\" data-end=\"3594\" data-col-size=\"sm\">Electrode Gap<\/td>\n<td data-col-size=\"sm\" data-start=\"3594\" data-end=\"3610\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3611\" data-end=\"3641\">\n<td data-start=\"3611\" data-end=\"3625\" data-col-size=\"sm\">Active Area<\/td>\n<td data-col-size=\"sm\" data-start=\"3625\" data-end=\"3641\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3642\" data-end=\"3673\">\n<td data-start=\"3642\" data-end=\"3657\" data-col-size=\"sm\">Overall Size<\/td>\n<td data-start=\"3657\" data-end=\"3673\" data-col-size=\"sm\">Customizable<\/td>\n<\/tr>\n<tr data-start=\"3674\" data-end=\"3728\">\n<td data-start=\"3674\" data-end=\"3690\" data-col-size=\"sm\">Connector End<\/td>\n<td data-col-size=\"sm\" data-start=\"3690\" data-end=\"3728\">Gold pad \/ conductive contact area<\/td>\n<\/tr>\n<tr data-start=\"3729\" data-end=\"3775\">\n<td data-start=\"3729\" data-end=\"3741\" data-col-size=\"sm\">Packaging<\/td>\n<td data-col-size=\"sm\" data-start=\"3741\" data-end=\"3775\">Individual packaging available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"3777\" data-end=\"3780\" \/>\n<h2 data-section-id=\"8ddthm\" data-start=\"3782\" data-end=\"3810\">Website Short Description<\/h2>\n<p data-start=\"3812\" data-end=\"4207\"><strong data-start=\"3812\" data-end=\"4207\">100 \u03bcm Polyester Flexible Interdigitated Gold Electrode is designed for electrochemical sensors, biosensors, impedance testing, conductivity measurement, microfluidic devices, and flexible electronic research. The gold interdigitated structure provides a defined sensing area, excellent conductivity, and good compatibility with surface modification. Custom electrode patterns are available.<\/strong><\/p>","protected":false},"featured_media":5648,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"tags":[],"products":[278,268],"class_list":["post-5647","product","type-product","status-publish","has-post-thumbnail","hentry","products-gold-electrode","products-metal-electrode"],"acf":[],"_links":{"self":[{"href":"https:\/\/oqitop.com\/fr\/wp-json\/wp\/v2\/product\/5647","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oqitop.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/oqitop.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oqitop.com\/fr\/wp-json\/wp\/v2\/media\/5648"}],"wp:attachment":[{"href":"https:\/\/oqitop.com\/fr\/wp-json\/wp\/v2\/media?parent=5647"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oqitop.com\/fr\/wp-json\/wp\/v2\/tags?post=5647"},{"taxonomy":"products","embeddable":true,"href":"https:\/\/oqitop.com\/fr\/wp-json\/wp\/v2\/products?post=5647"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}