 {"id":5643,"date":"2026-05-05T10:55:47","date_gmt":"2026-05-05T02:55:47","guid":{"rendered":"https:\/\/oqitop.com\/?post_type=product&#038;p=5643"},"modified":"2026-05-05T10:55:47","modified_gmt":"2026-05-05T02:55:47","slug":"gold-disk-working-electrode-1-6-mm-for-electrochemical-experiments","status":"publish","type":"product","link":"https:\/\/oqitop.com\/ja\/gold-disk-working-electrode-1-6-mm-for-electrochemical-experiments\/","title":{"rendered":"Gold Disk Working Electrode 1\u20136 mm for Electrochemical Experiments"},"content":{"rendered":"<h2 data-section-id=\"1bw7wp4\" data-start=\"823\" data-end=\"845\">\u88fd\u54c1\u8aac\u660e<\/h2>\n<p data-start=\"847\" data-end=\"1101\">Gold Disk Working Electrode is made with a high-purity gold disk embedded in an insulating electrode body. The exposed gold surface acts as the active working electrode area, while the surrounding insulating material helps define a precise reaction area.<\/p>\n<p data-start=\"1103\" data-end=\"1380\">Gold has excellent electrical conductivity, stable electrochemical properties, and strong surface modification capability. It is widely used in electrochemical sensors, biosensors, self-assembled monolayers, redox reaction studies, catalytic research, and analytical chemistry.<\/p>\n<p data-start=\"1382\" data-end=\"1584\">The electrode is available in different disk diameters from <strong data-start=\"1442\" data-end=\"1458\">1 mm to 6 mm<\/strong>, allowing users to choose the appropriate working area according to experimental current, sensitivity, and test requirements.<\/p>\n<hr data-start=\"1586\" data-end=\"1589\" \/>\n<h2 data-section-id=\"1ma7m6t\" data-start=\"1591\" data-end=\"1606\">Key Features<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1608\" data-end=\"2103\">\n<thead data-start=\"1608\" data-end=\"1630\">\n<tr data-start=\"1608\" data-end=\"1630\">\n<th class=\"\" data-start=\"1608\" data-end=\"1615\" data-col-size=\"sm\">\u9805\u76ee<\/th>\n<th class=\"\" data-start=\"1615\" data-end=\"1630\" data-col-size=\"md\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1641\" data-end=\"2103\">\n<tr data-start=\"1641\" data-end=\"1693\">\n<td data-start=\"1641\" data-end=\"1656\" data-col-size=\"sm\">Product Type<\/td>\n<td data-start=\"1656\" data-end=\"1693\" data-col-size=\"md\">Electrochemical Working Electrode<\/td>\n<\/tr>\n<tr data-start=\"1694\" data-end=\"1728\">\n<td data-start=\"1694\" data-end=\"1715\" data-col-size=\"sm\">Electrode Material<\/td>\n<td data-col-size=\"md\" data-start=\"1715\" data-end=\"1728\">Gold \/ Au<\/td>\n<\/tr>\n<tr data-start=\"1729\" data-end=\"1759\">\n<td data-start=\"1729\" data-end=\"1746\" data-col-size=\"sm\">Active Surface<\/td>\n<td data-col-size=\"md\" data-start=\"1746\" data-end=\"1759\">Gold disk<\/td>\n<\/tr>\n<tr data-start=\"1760\" data-end=\"1814\">\n<td data-start=\"1760\" data-end=\"1776\" data-col-size=\"sm\">Disk Diameter<\/td>\n<td data-col-size=\"md\" data-start=\"1776\" data-end=\"1814\">1 mm, 2 mm, 3 mm, 4 mm, 5 mm, 6 mm<\/td>\n<\/tr>\n<tr data-start=\"1815\" data-end=\"1878\">\n<td data-start=\"1815\" data-end=\"1832\" data-col-size=\"sm\">Electrode Body<\/td>\n<td data-col-size=\"md\" data-start=\"1832\" data-end=\"1878\">PTFE \/ PEEK \/ glass \/ epoxy body available<\/td>\n<\/tr>\n<tr data-start=\"1879\" data-end=\"1933\">\n<td data-start=\"1879\" data-end=\"1893\" data-col-size=\"sm\">Application<\/td>\n<td data-start=\"1893\" data-end=\"1933\" data-col-size=\"md\">Electrochemical testing and analysis<\/td>\n<\/tr>\n<tr data-start=\"1934\" data-end=\"1969\">\n<td data-start=\"1934\" data-end=\"1944\" data-col-size=\"sm\">Surface<\/td>\n<td data-col-size=\"md\" data-start=\"1944\" data-end=\"1969\">Polished gold surface<\/td>\n<\/tr>\n<tr data-start=\"1970\" data-end=\"2030\">\n<td data-start=\"1970\" data-end=\"1983\" data-col-size=\"sm\">Connection<\/td>\n<td data-col-size=\"md\" data-start=\"1983\" data-end=\"2030\">Banana plug \/ copper rod \/ custom connector<\/td>\n<\/tr>\n<tr data-start=\"2031\" data-end=\"2103\">\n<td data-start=\"2031\" data-end=\"2047\" data-col-size=\"sm\">Customization<\/td>\n<td data-col-size=\"md\" data-start=\"2047\" data-end=\"2103\">Diameter, length, body material, connector available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"2105\" data-end=\"2108\" \/>\n<h2 data-section-id=\"1nfol9\" data-start=\"2110\" data-end=\"2142\">Available Gold Disk Diameters<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2144\" data-end=\"2321\">\n<thead data-start=\"2144\" data-end=\"2178\">\n<tr data-start=\"2144\" data-end=\"2178\">\n<th class=\"\" data-start=\"2144\" data-end=\"2155\" data-col-size=\"sm\">\u76f4\u5f84<\/th>\n<th class=\"\" data-start=\"2155\" data-end=\"2178\" data-col-size=\"sm\">Approx. Active Area<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2189\" data-end=\"2321\">\n<tr data-start=\"2189\" data-end=\"2211\">\n<td data-start=\"2189\" data-end=\"2196\" data-col-size=\"sm\">1 mm<\/td>\n<td data-col-size=\"sm\" data-start=\"2196\" data-end=\"2211\">0.00785 cm\u00b2<\/td>\n<\/tr>\n<tr data-start=\"2212\" data-end=\"2233\">\n<td data-start=\"2212\" data-end=\"2219\" data-col-size=\"sm\">2 mm<\/td>\n<td data-col-size=\"sm\" data-start=\"2219\" data-end=\"2233\">0.0314 cm\u00b2<\/td>\n<\/tr>\n<tr data-start=\"2234\" data-end=\"2255\">\n<td data-start=\"2234\" data-end=\"2241\" data-col-size=\"sm\">3 mm<\/td>\n<td data-start=\"2241\" data-end=\"2255\" data-col-size=\"sm\">0.0707 cm\u00b2<\/td>\n<\/tr>\n<tr data-start=\"2256\" data-end=\"2277\">\n<td data-start=\"2256\" data-end=\"2263\" data-col-size=\"sm\">4 mm<\/td>\n<td data-col-size=\"sm\" data-start=\"2263\" data-end=\"2277\">0.1256 cm\u00b2<\/td>\n<\/tr>\n<tr data-start=\"2278\" data-end=\"2299\">\n<td data-start=\"2278\" data-end=\"2285\" data-col-size=\"sm\">5 mm<\/td>\n<td data-col-size=\"sm\" data-start=\"2285\" data-end=\"2299\">0.1963 cm\u00b2<\/td>\n<\/tr>\n<tr data-start=\"2300\" data-end=\"2321\">\n<td data-start=\"2300\" data-end=\"2307\" data-col-size=\"sm\">6 mm<\/td>\n<td data-col-size=\"sm\" data-start=\"2307\" data-end=\"2321\">0.2827 cm\u00b2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"2323\" data-end=\"2326\" \/>\n<h2 data-section-id=\"1klznxy\" data-start=\"2328\" data-end=\"2346\">Main Advantages<\/h2>\n<ul data-start=\"2348\" data-end=\"2763\">\n<li data-section-id=\"17qkoqp\" data-start=\"2348\" data-end=\"2383\">High-purity gold active surface<\/li>\n<li data-section-id=\"24ih3x\" data-start=\"2384\" data-end=\"2421\">Excellent electrical conductivity<\/li>\n<li data-section-id=\"1mhldy7\" data-start=\"2422\" data-end=\"2460\">Stable electrochemical performance<\/li>\n<li data-section-id=\"qcyvka\" data-start=\"2461\" data-end=\"2499\">Smooth and polishable disk surface<\/li>\n<li data-section-id=\"10lmjq8\" data-start=\"2500\" data-end=\"2549\">Suitable for repeated electrochemical testing<\/li>\n<li data-section-id=\"yyvldu\" data-start=\"2550\" data-end=\"2584\">Precise working electrode area<\/li>\n<li data-section-id=\"oae62m\" data-start=\"2585\" data-end=\"2628\">Compatible with three-electrode systems<\/li>\n<li data-section-id=\"1bc1zpf\" data-start=\"2629\" data-end=\"2667\">Available in 1\u20136 mm disk diameters<\/li>\n<li data-section-id=\"1x9bia5\" data-start=\"2668\" data-end=\"2725\">Suitable for surface modification and sensor research<\/li>\n<li data-section-id=\"14uuw6v\" data-start=\"2726\" data-end=\"2763\">Custom electrode design available<\/li>\n<\/ul>\n<hr data-start=\"2765\" data-end=\"2768\" \/>\n<h2 data-section-id=\"mu966k\" data-start=\"2770\" data-end=\"2785\">\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2787\" data-end=\"3476\">\n<thead data-start=\"2787\" data-end=\"2816\">\n<tr data-start=\"2787\" data-end=\"2816\">\n<th class=\"\" data-start=\"2787\" data-end=\"2801\" data-col-size=\"sm\">Application<\/th>\n<th class=\"\" data-start=\"2801\" data-end=\"2816\" data-col-size=\"md\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2827\" data-end=\"3476\">\n<tr data-start=\"2827\" data-end=\"2892\">\n<td data-start=\"2827\" data-end=\"2848\" data-col-size=\"sm\">Cyclic Voltammetry<\/td>\n<td data-col-size=\"md\" data-start=\"2848\" data-end=\"2892\">Used as working electrode for CV testing<\/td>\n<\/tr>\n<tr data-start=\"2893\" data-end=\"2960\">\n<td data-start=\"2893\" data-end=\"2920\" data-col-size=\"sm\">Electrochemical Analysis<\/td>\n<td data-col-size=\"md\" data-start=\"2920\" data-end=\"2960\">Suitable for redox reaction analysis<\/td>\n<\/tr>\n<tr data-start=\"2961\" data-end=\"3037\">\n<td data-start=\"2961\" data-end=\"2987\" data-col-size=\"sm\">Electrochemical Sensors<\/td>\n<td data-col-size=\"md\" data-start=\"2987\" data-end=\"3037\">Commonly used in sensor and biosensor research<\/td>\n<\/tr>\n<tr data-start=\"3038\" data-end=\"3113\">\n<td data-start=\"3038\" data-end=\"3061\" data-col-size=\"sm\">Surface Modification<\/td>\n<td data-col-size=\"md\" data-start=\"3061\" data-end=\"3113\">Suitable for SAMs and functional coating studies<\/td>\n<\/tr>\n<tr data-start=\"3114\" data-end=\"3175\">\n<td data-start=\"3114\" data-end=\"3133\" data-col-size=\"sm\">Electrocatalysis<\/td>\n<td data-col-size=\"md\" data-start=\"3133\" data-end=\"3175\">Used for catalytic reaction evaluation<\/td>\n<\/tr>\n<tr data-start=\"3176\" data-end=\"3249\">\n<td data-start=\"3176\" data-end=\"3199\" data-col-size=\"sm\">Analytical Chemistry<\/td>\n<td data-col-size=\"md\" data-start=\"3199\" data-end=\"3249\">Used in laboratory electrochemical measurement<\/td>\n<\/tr>\n<tr data-start=\"3250\" data-end=\"3324\">\n<td data-start=\"3250\" data-end=\"3270\" data-col-size=\"sm\">Corrosion Testing<\/td>\n<td data-col-size=\"md\" data-start=\"3270\" data-end=\"3324\">Used in selected electrochemical corrosion studies<\/td>\n<\/tr>\n<tr data-start=\"3325\" data-end=\"3398\">\n<td data-start=\"3325\" data-end=\"3344\" data-col-size=\"sm\">Battery Research<\/td>\n<td data-col-size=\"md\" data-start=\"3344\" data-end=\"3398\">Used for material electrochemical behavior testing<\/td>\n<\/tr>\n<tr data-start=\"3399\" data-end=\"3476\">\n<td data-start=\"3399\" data-end=\"3420\" data-col-size=\"sm\">Fuel Cell Research<\/td>\n<td data-col-size=\"md\" data-start=\"3420\" data-end=\"3476\">Suitable for catalyst and electrode reaction studies<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>","protected":false},"featured_media":5644,"template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"tags":[],"products":[278,268],"class_list":["post-5643","product","type-product","status-publish","has-post-thumbnail","hentry","products-gold-electrode","products-metal-electrode"],"acf":[],"_links":{"self":[{"href":"https:\/\/oqitop.com\/ja\/wp-json\/wp\/v2\/product\/5643","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oqitop.com\/ja\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/oqitop.com\/ja\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oqitop.com\/ja\/wp-json\/wp\/v2\/media\/5644"}],"wp:attachment":[{"href":"https:\/\/oqitop.com\/ja\/wp-json\/wp\/v2\/media?parent=5643"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oqitop.com\/ja\/wp-json\/wp\/v2\/tags?post=5643"},{"taxonomy":"products","embeddable":true,"href":"https:\/\/oqitop.com\/ja\/wp-json\/wp\/v2\/products?post=5643"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}