High-Purity Nickel Sheet Electrode for Electrochemical Laboratory Research - Nickel Foam, Copper Foam, Titanium Foam, Aluminum Foam, Foam Metal Manufacturers

CATEGORIES

CONTACT US

High-Purity Nickel Sheet Electrode for Electrochemical Laboratory Research

Product Description

High-Purity Nickel Sheet Electrode for Electrochemical Laboratory Research

Short Product Name

Nickel Sheet Electrode

SEO Product Title

High-Purity Nickel Sheet Electrode 10×10×0.1 mm for Electrochemical Testing

URL Slug

high-purity-nickel-sheet-electrode

SEO Meta Description

High-purity nickel sheet electrode with 10×10×0.1 mm ultra-thin nickel tip for electrochemical testing, conductivity analysis, corrosion research, and laboratory R&D. Custom rod length, rod diameter, connector, and structure available.

SEO Keywords

nickel sheet electrode, high purity nickel electrode, nickel plate electrode, nickel foil electrode, nickel square electrode, nickel working electrode, nickel counter electrode, nickel auxiliary electrode, electrochemical nickel electrode, nickel electrode for electrochemistry, nickel electrode for electrochemical testing, nickel electrode for corrosion research, laboratory nickel electrode, custom nickel sheet electrode, PTFE rod nickel electrode, PEEK rod nickel electrode


Product Description

Our High-Purity Nickel Sheet Electrode is designed for electrochemical testing, conductivity analysis, corrosion research, material evaluation, and laboratory R&D applications. The electrode features a 10×10×0.1 mm ultra-thin nickel sheet tip, a PTFE or PEEK insulating rod body, a sealing O-ring, and a metal connector pin for convenient connection with electrochemical workstations, potentiostats, electrode holders, and laboratory testing systems.

The nickel sheet tip is thin, flat, and lightweight, providing a stable conductive surface for electrochemical measurements. Compared with a thick metal block, the 0.1 mm nickel sheet is more suitable for laboratory testing where a defined thin electrode surface, easy immersion, and stable experimental consistency are required.

We support custom nickel sheet size, thickness, rod length, rod diameter, connector type, insulating rod material, and overall electrode structure. Whether you need a standard 10×10×0.1 mm nickel sheet electrode or a customized nickel electrode based on your experimental design, we can provide flexible OEM / ODM solutions for academic laboratories, research institutes, and industrial testing projects.


Key Features

Ultra-Thin Nickel Sheet Tip

Equipped with a 10×10×0.1 mm nickel sheet tip, designed as a thin flat electrode surface rather than a thick block.

High-Purity Nickel Material

Made with quality nickel material for stable conductivity and reliable electrochemical performance.

PTFE / PEEK Insulating Rod Options

The insulating rod can be made from PTFE, PEEK, or other custom materials according to chemical compatibility and testing requirements.

Stable O-Ring Structure

The O-ring helps secure the electrode structure and supports stable laboratory operation during testing.

Convenient Connector Pin

The metal connector pin allows easy connection with electrochemical workstations, potentiostats, and electrode holders.

Customizable Electrode Design

Nickel sheet size, thickness, rod length, rod diameter, connector type, and overall structure can be customized on request.


Specifications

Item Specification
Product Name Nickel Sheet Electrode
Material High-Purity Nickel
Electrode Type Sheet Electrode / Plate Electrode
Nickel Sheet Size 10 × 10 mm
Nickel Sheet Thickness 0.1 mm
Nickel Tip Shape Square Sheet / Custom Shape
Insulating Rod PTFE / PEEK / Custom Available
Connector Pin Metal Pin / Custom Connector
Sealing Part O-Ring
Rod Length Customizable
Rod Diameter Customizable
Surface Smooth Nickel Sheet Surface
Application Electrochemical Testing / Laboratory Research
Custom Service Sheet Size, Thickness, Rod Length, Connector, Structure

Applications

  • Electrochemical testing
  • Three-electrode system experiments
  • Conductivity analysis
  • Corrosion research
  • Material performance evaluation
  • Laboratory R&D
  • Beaker experiments
  • Electrochemical cell testing
  • Nickel working electrode applications
  • Nickel counter electrode applications
  • Nickel auxiliary electrode applications
  • Battery material research
  • Catalyst research
  • Sensor research
  • Academic experiments
  • Industrial material testing

Product Advantages

Thin Sheet Design for Laboratory Testing

The 0.1 mm nickel sheet tip is thin and flat, making it suitable for electrochemical experiments requiring a lightweight and defined electrode surface.

Stable Conductive Performance

Nickel provides good electrical conductivity and supports stable current transfer during electrochemical measurements.

Easy Immersion and Operation

The rod-type structure makes the electrode convenient to place into beakers, electrochemical cells, three-electrode systems, and laboratory fixtures.

Flexible Custom Processing

Nickel sheet size, thickness, rod length, rod diameter, connector pin, and insulating rod material can be customized according to your testing system.

OEM / ODM Support

Custom drawings, special electrode structures, different nickel sheet sizes, and customized packaging are available for research and industrial projects.


FAQ

Is the nickel sheet tip a thick block?

No. The nickel tip is an ultra-thin sheet electrode, with a standard size of 10×10×0.1 mm.

Can the nickel sheet size be customized?

Yes. Nickel sheet size, thickness, shape, rod length, rod diameter, and connector type can be customized according to your experimental requirements.

Can I choose PTFE or PEEK as the insulating rod material?

Yes. PTFE and PEEK insulating rod options are available. The material can be selected according to chemical compatibility and testing conditions.

What is this nickel sheet electrode used for?

It is commonly used for electrochemical testing, conductivity analysis, corrosion research, material evaluation, three-electrode system experiments, and laboratory R&D.

Can this electrode be used in a three-electrode system?

Yes. It can be used as a working electrode, counter electrode, or auxiliary electrode depending on your experimental design.

Do you support OEM / ODM customization?

Yes. We support custom size, custom structure, custom material selection, custom connector, and OEM / ODM processing services.

Leave Your Message

Products Recommended

Email: James@oqitop.com WhatsApp: +8615606950920 WeChat:18659227661