High-Purity Platinum Wire Electrode for Precision Research

CATEGORIAS

CONTACTE-NOS

High-Purity Platinum Wire Electrode (99.99% Pt) – Precision Spiral & Straight Designs with Customizable Lengths for Laboratory Research

Descrição do produto

Custom Platinum Wire Electrodes

 

Introdução

  1. Crafted from ≥99.99% high-purity platinum, our wire electrodes are designed to meet the most demanding standards of modern electrochemical analysis. Platinum’s exceptional chemical inertness and high exchange current density make these electrodes the ideal choice for applications ranging from Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) to complex electro-synthesis. The high-purity material ensures minimal background interference and prevents sample contamination, providing researchers with ultra-stable potential response and reproducible data even in aggressive acidic or alkaline environments.
  2. We offer extensive customization options to ensure our platinum wire electrodes integrate perfectly with your specific electrochemical cells. Whether you require a straight wire, a high-surface-area spiral (coil), or a U-shaped configuration, we can manufacture to your exact specifications. You can define the wire diameter (from ultra-fine 0.1mm to robust 2.0mm), total length, and the insulation material—typically high-grade PTFE or PEEK for superior chemical resistance. Each electrode is precision-welded to a conductive rod or lead wire and meticulously cleaned, ensuring it is ready for immediate use in fuel cell research, sensor development, or metal deposition studies.

Especificações

Tipo Platinum Sheet / Plate / Disc / Strip / Pt Electrode
Material Grade High‑purity Platinum (e.g., ≥Pt 99.95%, 99.99%, 99.999% electronic/analytical grade); specialized Pt alloys (e.g., Pt‑Ir, Pt‑Rh, Pt‑Au) available on request
Pureza Typically ≥99.95%, ≥99.99%, or ≥99.999% Pt (ultra‑high purity for highly stable electrochemical behavior, low background current, and long‑term durability)
Formulário Flat sheet, plate, circular disc, strip, ribbon, or ultra‑thin foil; supplied as single pieces, matched sets, or bulk lots for laboratory and pilot‑scale use
Espessura Customizable (typically 0.01 mm – 5 mm; ultra‑thin foils available for micro‑electrode, MEMS, and microfluidic sensor applications)
Tamanho e forma Fully customizable dimensions; precision‑cut rectangles, squares, round discs, rings, grids, and complex CNC‑machined geometries according to drawings or CAD files
Surface Finish Mill finish, bright/mirror‑polished, brushed, matte, sanded, or micro‑textured to optimize electrochemical active area, wetting properties, and coating adhesion
Surface Treatment / Coating Bare platinum (standard), chemically cleaned/degreased, electrochemically polished, activated surfaces, or functionalized (e.g., catalyst layers, Pt black) for fuel cells, sensors, and advanced electrochemistry
Hole / Slot / Mesh Design Precision drilled or laser‑cut holes, mounting slots, perforated patterns, or platinum mesh/expanded structures to enhance electrolyte access, gas diffusion, and mass transfer
Corrosion Performance Exceptional chemical inertness and corrosion resistance in most acidic, neutral, and alkaline electrolytes; ideal as a stable working, counter, or inert electrode in harsh electrochemical environments
Mechanical Strength High‑temperature stability and good mechanical strength; suitable for cutting, bending, spot‑welding, and fine machining; easy to join with wires, tabs, and conductive leads
Operating Temperature Suitable from low temperatures up to very high‑temperature electrochemical and catalytic applications; melting point approx. 1768 °C (recommended operation well below melting point)
Surface Flatness Tight control of thickness tolerance, roughness, and flatness to ensure uniform contact resistance, highly even current distribution, and reproducible electrochemical response
Application Range Electrochemical research (CV, LSV, EIS), fuel cell and electrolyzer electrodes, electrocatalysis and hydrogen evolution/oxygen reduction studies, corrosion and passivation tests, reference and counter electrodes, biosensors, medical and neural interfaces, high‑temperature catalysis, and advanced materials research
Customization Full support for laser/water‑jet cutting, precision stamping, CNC machining, micro‑patterning, tab/lead welding, surface activation/functionalization, assembly into electrode holders, and clean‑room packaging for high‑purity Pt electrodes suitable for demanding R&D and industrial applications

Dimensões de referência

0.1mm*5mm*10mm 0.2mm*5mm*10mm 0.1mm*10mm*20mm
0.2mm*20mm*20mm 0.3mm*20mm*30mm 0.1mm*20mm*50mm
0.2mm*30mm*100mm 0.1to 0.5mm*50mm*50mm O tamanho pode ser personalizado

To customize various metal electrodes, please click the picture below for details:

 

Stainless Steel Electrode
 

Titanium Electrode
 

Nickel Electrode
 

Platinum Electrode
 

Gold Electrode
 

Silver Electrode
 

Aluminum Electrode
 

Copper Electrode

Deixe a sua mensagem

Produtos recomendados

E-mail: James@oqitop.com WhatsApp: +8615606950920 WeChat:18659227661